Part # M-100D, Barymat M-100D
larger image
Barymat M-100D has a 1.0 lb. per sq. ft. barrier combined with a deep embossed vinyl 'carpet-like' wear surface and a 0.25 in. polyurethane foam spacer. It is designed for applications that require high sound transmission loss, good heat insulation and abrasion resistance. This floor mat is easy to install and is suitable for permanent or semi-permanent installations.
Typical Physical Properties
·
Applications and Product Data
·
Performance Data
·
Transmission Loss
Typical Physical Properties
Thermal Conductivity of Foam at 75°F (24°C)
ASTM C 518 — 0.27 Btu. in. / hr. ft.² ºF
Flammability
MVSS 302 - Passes
Composite Weight
1.2 lb. / sq. ft.
Applications and Product Data
Uses
Vehicle Floors and Fire Wall Barrier
Control Room Floors
BARYMAT M-100D is easy to apply and can be cut with common utility knives. For secure and permanent installations use specified adhesive - available from FirwinCorp.
Thickness
0.375 in. - overall composite thickness.
Standard Dimensions
Sheets:
54" wide X 72", untrimmed (27 sq.ft.)
CUSTOM TRIMMING AND DIE CUTTING CAN BE PROVIDED
Performance Data
Performance data is an extract from NRC - Ottawa report on tests according to ASTME 90-90 with material adhered to 16 ga. steel.
>
NOTICE:
Stated performance data is based on recognized testing methods. Product performance can be affected by field conditions and installation methods. Users of these products are responsible for determining suitability for their application and compliance with any legal provisions including those relating to health and safety.
Transmission Loss
Frequency (Hz)
Transmission Loss (dB) M - 100D
80
23
100
22
125
22
160
22
200
22
250
22
315
21
400
24
500
28
630
32
800
37
1000
41
1250
45
1600
47
2000
47
2500
47
3150
51
4000
55
5000
58
6300
58
STC
33